Qualität KDP210Q Differenzdrucktransmitter Fabrik

KDP210Q Differenzdrucktransmitter

Product Description: The DPT Differential Pressure Transmitter is a versatile and reliable product designed for accurate pressure measurement in various industrial applications. With multiple output signal options including 4-20 mA(2 Wire), 0-5V/0-10VDC(3 wire), RS-485, and customization available, this transmitter offers flexibility to suit different system requirements. Operating effectively in a wide temperature range from -40°C to +70°C, the DPT transmitter can withstand
Qualität KDP110 Differenzdrucktransmitter Fabrik

KDP110 Differenzdrucktransmitter

0-±200pa IP65 house protection filter differential pressure sensor for Pharmaceutical clean rooms Description KDP110 series differential pressure transmitter is a relatively cheap price, but the function is simple, the measurement range can only be adjusted by the DIP switch, and there is no display, which can meet the customer's requirements for the price, but at the same time we guarantee the quality and accuracy . Feature Ranges from -25/+25Pa to -10000/+10000Pa (according
Qualität KDP210 Differenzdrucktransmitter Fabrik

KDP210 Differenzdrucktransmitter

KDP210 Differential Pressure Transmitter
Qualität Differenzdrucktransmitter der KDP110-Serie (undurchsichtige Hülle) Fabrik

Differenzdrucktransmitter der KDP110-Serie (undurchsichtige Hülle)

100pa -1000pa 4-20ma 2 Wire KDP Differential Pressure Transmitter Sensor HVAC Description KDP110 difffferential pressure transmitter has the characteristics of high accuracy,ultra-low adjustable range and fast response. It is widely used in the clean rooms of electronic and pharmaceutical factories, as well as the automatic control system of commercial buildings, HVAC air conditioning processor system,medical centers and transportation hubs. Feature Ranges from -25/+25Pa to
Qualität KDP210AC Differenzdrucktransmitter Fabrik

KDP210AC Differenzdrucktransmitter

KDP210AC RS485 LCD display differential pressure transmitter for clean room Description KDP210AC series differential pressure transmitters are available with and without screen for customers to choose from with high precision, ultra-low & adjustable range, fast response characteristics. Feature Ranges from -25/+25Pa to -10000/+10000Pa (according to models) Auto zero manual calibration Voltage, current, digital signal output Standard accuracy
Qualität KDP210AC Differenzdrucktransmitter mit IP65-Schutz, LCD-Display und manueller Kalibrierung für HVAC und Reinräume Fabrik

KDP210AC Differenzdrucktransmitter mit IP65-Schutz, LCD-Display und manueller Kalibrierung für HVAC und Reinräume

KDP210AC Differential Pressure Transmitter Product Overview Measurement Media Air, neutral gases, dry gases, and other gases Range Minimum ±25 Pa / 0-25 Pa Maximum 0-10 kPa Common ranges: ±100 Pa, ±1000 Pa, ±10000 Pa 0-0.125~1.5 kPa Output Signal 4-20mA (2/3-wire), 0-5V (3-wire), 0-10V (3-wire), RS485 (Modbus RTU) Power Supply 16-30VAC/DC (3-wire); 18-30VAC/DC (2-wire) Accuracy ±1% F.S Protection Rating IP65/NEMA4 Cable Connector M12 aviation connector Display LCD backlit
Qualität KDP210Q Mikro-Differenzdrucktransmitter mit IP65-Schutz und RS485-Ausgang Fabrik

KDP210Q Mikro-Differenzdrucktransmitter mit IP65-Schutz und RS485-Ausgang

KDP210Q Differential Pressure Transmitter Product Overview Measurement Media Air, neutral gases, dry gases, and other gases Range Minimum ±25 Pa / 0-25 PaMaximum 0-10 kPaCommon ranges: ±100 Pa, ±1000 Pa, ±10000 Pa0-0.125~1.5 kPa Output Signal 4-20mA (2/3-wire), 0-5V (3-wire), 0-10V (3-wire), RS485 (Modbus RTU) Power Supply 16-30VAC/DC (3-wire); 18-30VAC/DC (2-wire) Accuracy ±1% F.S Protection Rating IP65/NEMA4 Cable Gland M16*1.5 Display LCD backlit display Applications HVAC
Qualität KDP210 Differenzdrucktransmitter mit 4-20mA Ausgang IP65-Schutz und LCD-Display Fabrik

KDP210 Differenzdrucktransmitter mit 4-20mA Ausgang IP65-Schutz und LCD-Display

KDP210 Differential Pressure Transmitter Product Overview Measurement Media Air, neutral gases, dry gases, and other gases Range Minimum ±25 Pa / 0-25 PaMaximum 0-10 kPaCommon ranges: ±100 Pa, ±1000 Pa, ±10000 Pa0-0.125~1.5 kPa Output Signal 4-20mA (2/3-wire), 0-5V (3-wire), 0-10V (3-wire), RS485 (Modbus RTU) Power Supply 16-30VAC/DC (3-wire); 18-30VAC/DC (2-wire) Accuracy ±1% F.S Protection Rating IP65/NEMA4 Display LCD backlit display Applications HVAC and Energy Management
Qualität KDP110 Differenzdrucktransmitter mit 4-20mA Ausgangsleistung IP65-Schutz und schneller Reaktionszeit für industrielle Steuerung Fabrik

KDP110 Differenzdrucktransmitter mit 4-20mA Ausgangsleistung IP65-Schutz und schneller Reaktionszeit für industrielle Steuerung

KDP110 Differential Pressure Transmitter Product Overview Measurement Media Air, neutral gases, dry gases, and other gases Range Minimum ±25 Pa / 0-25 Pa Maximum 0-10 kPa Common ranges: ±100 Pa, ±1000 Pa, ±10000 Pa 0-0.125~1.5 kPa Output Signal 4-20mA (2/3-wire), 0-5V (3-wire), 0-10V (3-wire), RS485 (Modbus RTU) Power Supply 16-30VAC/DC (3-wire); 18-30VAC/DC (2-wire) Accuracy ±1% F.S Protection Rating IP65/NEMA4 Applications HVAC and Energy Management Systems Cleanroom